- Quiet, powerful Generac OHVI single-cylinder or V-Twin engines fueled by natural gas or LP gas.
- UL Listed remote-mounted pre-wired automatic transfer switch with 8, 10 or 12 circuit emergency load center for fast and efficient unattended transfer to generator when utility power fails.
- A standard weather protective enclosure with sound-absorbing panels protects generator from harmful weather and also reduces exterior noise levels. Includes key locks for security.
- Hinged top and removable front panel for easy serviceability.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in event of low oil pressure, high temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser runs the system for twelve minutes weekly to maintain top running condition.
- Installation system includes the pre-wired automatic transfer switch with built-in load center, 30' and 2' wiring harnesses, pre-wired external connection box, 1' flexible fuel line, "Do-It-Yourself" installation guide and a composite mounting pad.
|
 |
|
 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
| Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
| Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 72 Hz |
| Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10 seconds |
| Engine Cool-Down |
1 minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has stopped |
| 2 Amp Timed Trickle Battery Charger |
Standard |
| Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / test |
Start with starter control, unit stays on. If utility fails,transfer to load takes place |
|
|
 |
 |
 |
 |
 |
 |
Transfer Switch |
 |
 |
| No. of Poles |
2 |
| Current Rating (amps) |
100 |
| Voltage Rating (VAC) |
250 |
Utility Voltage Monitor (fixed)
Pick-up
Drop out |
80%
60% |
| Return to Utility |
Approx. 13 seconds |
| Exercises 7 minutes weekly |
Standard |
| UL Listed |
Standard |
| Dimensions (H" x W" x D") |
26.5 x 12.5 x 7 |
|
|
 |
| Go to 7, 12 & 15 kW specifications PDF |
|
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
| Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
70 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
| Engine
Warmup |
15
seconds |
| Engine
Cool-Down |
1
minute |
| Safety
Fuse |
Standard |
| |
|
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
| Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
 |
| Go
to 15 & 20 KW specifications PDF |
 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
| Start
/ Stop Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
70 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
| Engine
Warmup |
15
seconds |
| Engine
Cool-Down |
1
minute |
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Mode
Switch: Auto Switch |
Utility
failure/7 day exerciser |
| Auto
Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
| Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
 |
| Go
to 25 kW specifications PDF |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
| Start
/ Stop Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
70 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
| Engine
Warmup |
15
seconds |
| Engine
Cool-Down |
1
minute |
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
| Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
 |
| Go
to 45 kW spec PDF |
|
 |
 |
GUARDIAN
Portable
Generator Model |
12500 |
15000 |
| Model
Number |
04451 |
04582 |
| Rated
Watts |
12500 |
15000 |
| Surge
Watts |
18750 |
22500 |
| Voltage
(Vac) |
120/240 |
120/240 |
| Output
(A) |
104/52 |
125/62.5 |
| Engine
Type |
Generac
V-Twin
OHVI 760cc
27 HP
Electric Start |
Generac
V-Twin
OHVI 992cc
30 HP
Electric Start |
| Weight |
417 |
450 |
Dimensions
(H” x W” x L”)
Fully assembled with handle and wheel kit |
38.5
x 30.75 x 48.5 |
38.5
x 30.75 x 48.5 |
| Full
Pressure Lubrication |
X |
X |
| Single
Point Lifting |
X |
X |
| Spin-on
Oil Filter |
X |
X |
| Automotive
3-stage Air Filtration |
X |
X |
| Automatic
Idle Control |
X |
X |
| Lifetime
Carbon Excitation Brushes |
X |
X |
| Low
Oil Pressure Shutdown |
X |
X |
| Automatic
Voltage Regulation (AVR) |
X |
X |
| Solid
State Volt. Regulator |
X |
X |
| GFI
Protection |
X |
X |
| Anti-Vibration
System |
X |
X |
| Circuit
Breakers |
X |
X |
| Battery
Charge Cables |
X |
X |
| Maintenance
Free Battery |
X |
X |
| Full
1-1/4” Tubular Frame |
X |
X |
| Pneumatic
Wheel Kit |
X |
X |
| Electronic
Governor |
X |
X |
| MSRP
(Suggested Price) |
$2,475.00 |
$2,715.00 |
|
|
|